3com 1005 Manual De Usuario

Descargar
Página de 155
 
DUA1840-0AAA01
 
2-4
 
C
 
H
 
A
 
P
 
T
 
E
 
R
 
 2: 
 
I
 
N
 
S
 
T
 
A
 
L
 
L
 
A
 
T
 
I
 
O
 
N
 
 
 
A
 
N
 
D
 
 I
 
N
 
I
 
T
 
I
 
A
 
L
 
 S
 
E
 
T
 
U
 
P
 
Advice for Setting Backplane Connections and Avoiding Loops
 
Considerable care should be taken when setting backplane 
 
connections if there is more than one Switch 1005 installed in your 
 
MSH chassis. If more than one module has multiple connections 
 
enabled on the same VLAN, a network loop can occur, severely 
 
affecting network operation. 
 
For example, consider a pair of Switch modules where all four 
 
backplane connections are enabled and in the same VLAN. If a packet 
 
with a unicast destination address arrives on the backplane E1, 
 
destined for an end-station on backplane E2, both Switch modules will 
 
independently switch the packet onto E2, resulting in duplication. 
 
Packets with broadcast destination addresses will loop continuously 
 
between the two Switch modules. You can avoid this situation by 
 
following these guidelines:
 
If all ports on your network are in the same VLAN, you should connect 
 
all Switch 1005 modules via the Fast Ethernet connection, but only 
 
connect the internal Ethernet backplanes on one Switch 1005.
 
Alternatively, balance the load on your Switch 1005 modules more 
 
effectively by connecting one internal Ethernet connection to each 
 
Switch 1005.
 
If you have implemented multiple VLANs, put each internal Ethernet 
 
connection in a different VLAN on each Switch.