ROUBLESHOOTING
Troubleshooting Chart
Troubleshooting Chart
Symptom
Action
Cannot connect 
using Telnet, Web 
browser, or SNMP 
software
• Be sure to have configured the agent with a valid IP 
address, subnet mask and default gateway.
• Be sure that your management station has management 
VLAN access to the switch (default is VLAN 1). 
• Check that you have a valid network connection to the 
switch and that the port you are using has not been 
disabled.
• Check network cabling between the management station 
and the switch.
• If you cannot connect using Telnet, you may have exceeded 
the maximum number of concurrent Telnet sessions 
permitted. Try connecting again at a later time. 
Cannot access 
the on-board 
configuration 
program via a serial 
port connection
• Be sure to have set the terminal emulator program to 
VT100 compatible, 8 data bits, 1 stop bit, no parity and 
9600  bps. 
• Check that the null-modem serial cable conforms to the 
pin-out connections provided in Appendix B. 
Forgot or lost the 
password
• Reinstall the switch defaults or runtime code. Make a direct 
connection to the switch’s console port and power cycle 
the switch. During the POST diagnostics, access the 
firmware-download menu and select the appropriate 
options. See “Upgrading Firmware via the Serial Port” on 
page A-2 for more details.