Emerson 5150 Manual De Usuario

Descargar
Página de 32
A-4     Create Favorites folder, 3
rd
 Party Modbus Configuration 
Connectivity Module 
 
 
How to create a Favorites folder for ASCO 
device pages and copy it to another 
computer 
 
To create a favorites folder and copy it to another user’s 
computer, the administrator should follow these steps: 
 
1.  Open the first page and then pull down the Favorites 
manual and select Add to Favorites … This window 
will appear: 
 
 
2.  Click the New Folder button, type the new folder 
name as asco, then click the OK button. 
 
3.  Click folder asco and click OK
 
4.  Open the other pages one by one and click Add to 
Favorite, click folder asco, then click OK. 
 
5.  Once the administrator is done with saving all the 
pages, the following steps describe how to copy the 
asco folder from the administrator’s computer to 
another user’s computer. 
 
a.  For Windows XP, find the asco folder from directory 
‘c:documentd and settings\’user name’\favorites’. 
 
b.  Copy the asco folder into the corresponding path 
above. 
 
c.  Open browser and select address or name from 
favorite asco folder to view the device pages. 
 
Third Party Modbus Device Configuration 
 
The Connectivity Module supports the Modbus devices 
with Modbus/TCP portocol. The transmit and receiving 
data format are as follows: 
 
Read: 
Requests

Bytes 0, 1 Transaction ID. 
Usually zero when making a request, the server 
will copy them into the response. 
Bytes 2, 3 Protocol number. It must be zero. 
Byte 4 length (high byte) its always zero. 
Byte 5 length (low byte) of the following total bytes 
Byte 6 device address 
Byte 7 function code 
Bytes 8, 9 Modbus address of the starting transfer. 
Bytes 10, 11 number of word to transfer 
Response: 
Bytes 0, 1 Transaction ID. Its faithfully copied from the 
request 
Bytes 2, 3 Protocol number. It always is zero. 
Byte 4 length (high byte)  its always zero 
Byte 5 length (low byte) of the following total bytes 
Byte 6 device address 
Byte 7 function code 
Bytes 8 byte count of Modbus data. 
Bytes rest data values 
 
Configure the Connectivity Module to properly 
communicate with the other devices. The following 
items should be ready before you start to configure it: 
 
1.  Ethernet crossover cable. 
2.  Laptop with proper Ethernet connect ability. 
3.  Start Internet browser and type ‘IP 
address\config.htm’ on the browser address field. 
4.  This page should appear: 
 
From this page, 
configure all the 
parameters except 
reply timeout which 
needs to configured 
from client device. 
 
xxx