Selecting a Site
TigerSwitch 1000 units can be mounted in a standard 19-inch 
equipment rack or on a flat surface. Be sure to follow the 
guidelines below when choosing a location.
◆ The site should:
be at the center of all the devices you want to link and near 
a power outlet. 
be able to maintain its temperature within 0° to 50° C and 
its humidity within 5% to 95%, non-condensing
provide adequate space (approximately two inches) on all 
sides for proper air flow 
be accessible for installing, cabling and maintaining the 
devices 
allow the status LEDs to be clearly visible
◆ Make sure twisted-pair cable is always routed away from power 
lines, fluorescent lighting fixtures and other sources of electrical 
interference, such as radios, transmitters, etc.
◆ Make sure that a separate grounded power outlet that provides 
100 to 240 VAC, 50 to 60 Hz, is within 8 feet (2.44 m) of each 
device and is powered from an independent circuit breaker. As 
with any equipment, using a filter or surge suppressor is 
recommended.