SMSC LAN9311/LAN9311i
DATASHEET
 
6.2.1
Switch Fabric CSR Writes
To perform a write to an individual switch fabric register, the desired data must first be written into the
. The write cycle is initiated by
p e r f o r m i n g   a   s i n g l e   w r i t e   t o   t h e  
 with CSR_BUSY (bit 31) set, the CSR_ADDRESS field (bits 15:0) set to the
desired register address, the R_nW (bit 30) cleared, the AUTO_INC and AUTO_DEC fields cleared,
and the desired CSR byte enable bits selected (bits 19:16). The completion of the write cycle is
indicated by the clearing of the CSR_BUSY bit.
A second write method may be used which utilizes the auto increment/decrement function of the
 for writing sequential register
addresses. When using this method, the 
 must first be written with the auto increment(AUTO_INC) or auto
decrement(AUTO_DEC) bit set, the CSR_ADDRESS field written with the desired register address, the
R_nW bit cleared, and the desired CSR byte enable bits selected (typically all set). The write cycles
are then initiated by writing the desired data into the 
. The completion of the write cycle is indicated by the clearing of the
CSR_BUSY bit, at which time the address in the 
 is incremented or decremented accordingly. The user may then initiate a
subsequent write cycle by writing the desired data into the 
.
The third write method is to use the direct data range write function. Writes within the 
 address range automatically set
the appropriate register address, set all four byte enable bits (CSR_BE[3:0]), clears the R_nW bit, and
s e t s   t h e   C S R _ B U S Y   b i t   o f   t h e  
. The completion of the write cycle is indicated by the clearing of the
CSR_BUSY bit. Since the address range of the switch fabric CSRs exceeds that of the 
 address range, a sub-set of the
switch fabric CSRs are mapped to the 
 address range as detailed in 
 illustrates the process required to perform a switch fabric CSR write. The minimum wait
periods as specified in 
 are required where
noted.