SMSC SMC6516FF Manual De Usuario

Descargar
Página de 115
T
ROUBLESHOOTING
D-2
Troubleshooting Chart
Symptom
Action
Power LED is Off
No AC power.  Check connections 
between the switch, the power cord 
and the wall outlet.
Contact SMC Tech Support.
Power LED is Red
Internal or redundant power supply 
has failed or is disconnected.
Power LED is Green,
Internal power supply is operating 
Redundant Power LED properly; redundant power supply is 
is Off
not present or has been disconnected.
Power LED is Green,
Both internal and redundant power 
Redundant Power LED supplies are operating properly.
is Green
Power LED is Red,
Internal power supply has failed; 
Redundant Power LED device is being powered by redundant
is Green
power supply.
Power LED is Red,
Redundant power supply has failed; 
Redundant Power LED device is being powered by internal 
is Off
power supply.
Link LED is Off
Check connections between the
network device and the port,
including the wiring.
Check to be sure that the device is