Siemens 411 Manual De Usuario

Descargar
Página de 164
Issue 03/01 
10  Engineering Information 
MICROMASTER 411 & COMBIMASTER 411    Operating Instructions 
 
6SE6400-5CA00-0BP0 
141
 
10.8.4 BiCo 
Connections 
Table 10-4 
BiCo Connections (r0019 to r0054)  
 
 
 
 
COBO 
CO 
CO 
CO 
CO 
CO 
CO 
CO 
CO 
CO 
CO 
COBO 
COBO 
COBO 
Pa
r-
Nr
 
BiCo
 
 
 
001
9
 
002
0
 
002
1
 
002
4
 
002
5
 
002
6
 
002
7
 
003
4
 
003
6
 
003
7
 
003
9
 
005
2
 
005
3
 
005
4
 
Pa
ra
met
e
Nu
mber
 
So
u
rce
 
Na
me
 
F
u
nct
io
n
al
 G
ro
u
pi
ng 
CO/
B
O:
 BOP c
o
n
tr
o
l w
o
rd
 
CO:
 Fr
e
qu
e
nc
y set
p
o
in
CO:
 Ac
t.
 fr
eq
ue
ncy
 
CO: A
ct. o
u
tp
ut
 fr
equ
e
ncy 
CO: A
ct. o
u
tp
ut
 v
oltag
CO: A
ct. DC-li
nk
 v
o
lta
g
CO: A
ct. o
u
tp
ut
 c
urre
nt 
CO: Moto
r u
tili
za
tion 
CO: Drive
 ut
ili
zat
ion 
CO:
 Dr
iv
e t
e
mp
era
tur
es
 
CO: Po
we
co
ns
ump
tion
 [k
Wh] 
C
O
/B
O
: S
tatusw
ord 
C
O
/B
O
: S
tatusw
ord 
CO/BO: Co
n
tro
lw
o
rd 1
 
0731 CIB  BI: Binary output 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0800 CIB  BI: Download parameter set 0 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0801 CIB  BI: Download parameter set 1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0840 CIB  BI: CDS Bit 0 (local/remote) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0842 CIB BI: ON/OFF1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0844 CIB  BI: ON/OFF1 reverse 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0845 CIB  BI: 1. OFF2 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0848 CIB  BI: 2. OFF2 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0849 CIB  BI: 1. OFF3 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0852 CIB  BI: 2. OFF3 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1020 CIB BI: Pulse enable 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1021 CIB  BI: Fixed frequency selection bit 0 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1022 CIB  BI: Fixed frequency selection bit 1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1032 CIB  BI: Fixed frequency selection bit 2 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1035 CIB  BI: Enable MOP (UP-command) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1036 CIB  BI: Enable MOP (DOWN-command) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1055 CIB  BI: Enable JOG right 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1056 CIB  BI: Enable JOG left 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1074 CIB  BI: Disable additional setpoint 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1110 CIB  BI: Inhibit reverse direction 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1113 CIB BI: Reverse 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1124 CIB  BI: Enable JOG ramp times 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1140 CIB  BI: RFG enable 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1141 CIB  BI: RFG start 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1142 CIB  BI: RFG enable setpoint 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1230 CIB  BI: Enable DC braking 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2103 CIB  BI: 1. Faults acknowledgement 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2104 CIB  BI: 2. Faults acknowledgement 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2106 CIB  BI: External fault 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2220 CIB  BI: Fixed PID setpoint selection bit 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2221 CIB  BI: Fixed PID setpoint selection bit 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2222 CIB  BI: Fixed PID setpoint selection bit 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2235 CIB  BI: Enable MOP (UP-command) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2236 CIB  BI: Enable MOP (DOWN-command) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
0771 CIW CI: DAC 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1070 CID  CI: Main setpoint 
10 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1071 CIF  CI: Main setpoint scaling 
10 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1075 CID  CI: Additional setpoint 
10 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1076 CIF  CI: Additional setpoint scaling 
10 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2016 CIW  CI: PZD to BOP-Link (USS) 
20 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2019 CIW  CI: PZD to Comm-Link (USS) 
20 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2051 CIW  CI: PZD to CB 
20 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2200 CIB  BI: Enable PID controller 
22 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2253 CIF  CI: PID setpoint 
22 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2254 CIF  CI: PID trim source 
22 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2264 CIF  CI: PID feedback 
22