LOGO! functions 
 
4.4 Special functions list - SF 
 
LOGO! 
182
 
Manual, 04/2011, A5E03556174-01 
4.4.10 
Multiple function switch 
Short description 
Switch with two different functions:      
●  Pulse switch with off-delay 
●  Switch (permanent lighting) 
 
Symbol in LOGO! 
Wiring 
Description 
Input Trg 
A signal at input Trg (Trigger) sets output Q 
(permanent light) or resets Q with an off-delay. When 
active, output Q can be reset with a signal at input 
Trg. 
Input R 
A signal at input R resets the current time T
a
 and 
resets the output. 
Parameter 
T represents the off-delay time. The output is reset (1 
to 0 transition) when time T expires. 
T
L
 represents the time during which the output must 
be set to enable the permanent light function. 
T
!
 represents the on-delay for the prewarning time. 
T
!L
 represents the length of the prewarning time 
period. 
Retentivity:  
/ = No retentivity 
R = The status is retentive. 
4
7UJ
5
3DU
 
Output Q 
A signal at Trg switches on output Q. Depending on 
the length of the input at Trg, the output is switched 
off again or switched on permanently, or it is reset 
with a further signal at Trg. 
Parameters T, T
L
,T
!
 and T
!L
 
Note the defaults of the T parameters listed in topic Time response (Page 151). 
The off-delay time T, the permanent light time T
L
, the on-delay prewarning time T
!
 and the 
prewarning time period T
!L 
can be provided by the actual value of another already-
programmed function. You can use the actual values of the following functions:  
●  Analog comparator (Page 218) (actual value Ax – Ay) 
●  Analog threshold trigger (Page 213) (actual value Ax) 
●  Analog amplifier (Pag226) (actual value Ax) 
●  Analog multiplexer (Page 248) (actual value AQ) 
●  Analog ramp (Page 251) (actual value AQ) 
●  Mathematic instruction (Page 265) (actual value AQ) 
●  PI controller (Page 256) (actual value AQ) 
●  Up/down counter (Pag201) (actual value Cnt)