Página de 55
Magnum Quad-Series Fiber Switches 
Installation and User Guide (06/03) 
3.0  
INSTALLATION 
Before installing the equipment, it is necessary to take the 
following precautions: 
1.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, the environmental temperature around the equipment 
must be less than or equal to 50
0
C. 
2.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, adequate air flow must be maintained for proper and 
safe operation. 
3.) 
If the equipment is mounted in an enclosed or multiple rack 
system placement of the equipment must not overload or load 
unevenly the rack system. 
4.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, verify the equipment’s power requirements to prevent 
overloading of the building/s electrical circuits. 
5.)  
If the equipment is mounted in an enclosed or multiple rack 
assembly verify that the equipment has a reliable and 
uncompromised earthing path.
 
 
Installation:  This section describes installation of the Magnum Quad-Series Switches, 
as well as connection of the various Ethernet media types. 
 
3.1 
Locating Magnum Quad-Series Switches 
 
The location of a Magnum Quad-Series Switch is dependent on the physical 
layout of the network.  Typically the Switch is placed in a central wiring location where 
groups of network devices need to be connected in order to communicate with each 
other. These Switches are typically rack mounted in a wiring closet see Section 3.3.2 
below), but because they have rubber feet they can also be installed on a shelf or table 
top. The compact size of the 8-port QS580 unit allows it to be easily placed in an office 
or lab area, and it can also be either shelf of wall-mounted (see Section 3.3.1 below).  
 
Locate an AC receptacle that is within six feet (2 meters) of the intended 
Magnum Quad-Series site.  The rugged metal case of the Magnum Quad-Series will 
normally protect it from accidental damage in a lab or workplace setting.  Maintain an 
open view of the front to visually monitor the status LEDs.  Keep an open area around 
the unit so that cooling can occur from the small fan on the left side, while the unit is in 
operation. See figure below. 
ON
OFF
110-220
VAC
47-63Hz
1.0-0.5A
FAN  EXHAUST
Figure 3.1:  Location of 8-port Magnum QS580’s cooling fan exhaust 
 
15 
www  GarrettCom  com
.
.