= OPB - 1dB(for LED aging) - 1dB(for insertion loss) 
   Wors
Siemens’) web sites and catalogs to provide guidance to network designers and installers. 
 
Fiber  
Port 
odule 
Speed,  
 
Std. 
 
Mode
Std. 
km  
fdx 
(hdx) 
Wave
-
length
nm 
Cable 
Size 
µ
X’mitr 
Output 
P
T ,
 dB
R’cvr 
Sens.
P
R ,
dB
Worst 
OPB,
dB 
Worst* 
distance 
Km, fdx
typical
OPB,
dB 
typical* 
distance 
Km, fdx 
4.7 
Power Budget Calculations for Quad-Series QPM’s with Fiber  
Media 
 
 
Receiver Sensitivity and Transmitter Power are the parameters necessary to 
compute the power budget. To calculate the power budget of different fiber media 
installations using Magnum products, the following equations should be used: 
OPB (Optical Power Budget) = P
T
(min) - P
R
(min) 
      
 where P
= Transmitter Output Power, and P
R
 = Receiver Sensitivity 
 
   Worst case OPB 
t case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] 
 
where the “Cable Loss” for 62.5/125 and 50/125
µm
 (M.m) is 2.8 dB/km,  
 
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, 
 
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km 
 
The following data has been collected from component manufacturer’s (Agilent’s and 
M
QPM
10 Mb  Multi-
 
850 
62.5/125
100/140
-15.0 
-9.5 
-31 
-31 
14 
19.5 
5.9 
17 
23.5 
10-
FST 
ode
(2) 
 
50/125
-19.5 
-31 
9.5   
3.4 
13.5 

4.8 
FL
 
m
QPM- 
ST, MSC 
100Mb 
FX
 
Multi-
mode
(0.4) 
1300
62.5/125
50/125
-20 
-23.5 
-31 
-31 
9.0 
5.5 
2.5 
2.0 
14 
12 
M
4 
Q
 -31 14  28 
17.5  35 
PM-SSC 
FX
 
mode
(0.4)  1300
9/125 -15
100Mb  Single-
18+ 
QPM- 
100Mb  Multi-
1300
62.5/125
-20 
-31 
9.0 
3.0 
15.8
MTRJ 
FX
 
mode
(0.4) 
50/125
-23.5 
-31 
5.5 
2.0 
 
12.2 
5.5 
4.0 
QPM-
100Mb  Multi-
(0.4)  1300 62.5/125
-14 -31 15  5 
M
FX 
mode
V45 
16  5.7 
 
*
The use of either multi-mode or single-mode fiber to operate a
 Note:  
t 100Mbps speed 
over long distances (i.e., in excess of  approx. 400 meters) can be achieved 
only
 
full-duplex (factory default) setting for 100Mbps fiber ports must be used, 
• 
 
ca
P
h
 
f
ssive Atte
(Attenuation = C
s
 
 
if the following factors are both applied: 
• 
The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the 
and 
The
pa
worst-
se O B of t
n. 
e fiber link must be greater than the  iber cable’s 
n
o
able lo
uati
s   L
+ ED aging loss + Insertion loss + safety factor)
 
 
34 