Magnum 6K8-Series Industrial Field Switch             Installation and User Guide   03/06) 
 
22
www  GarrettCom  com
.
.
 
 
3.0 Installation 
 
Before installing the equipment, please note the following UL/CSA60950 product 
safety listing requirements. 
1)The external power supply for 24VDC units shall be a Listed, Direct Plug In power 
unit, marked Class 2, or a Listed ITE Power Supply, which has a suitably rated output 
voltage (i.e. 24VDC), and suitably rated output current. 
 
 Mounting Instructions -  
 
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the 
operating ambient temperature of the rack environment may be greater than room 
ambient. Therefore, consideration should be given to installing the equipment in an 
environment compatible with the maximum ambient temperature (Tma) specified by the 
manufacturer. 
 
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the 
amount of airflow  required for safe operation of the equipment is not compromised. 
 
C) Mechanical Loading - Mounting of the equipment in the rack should be such that a 
hazardous condition is not achieved due to uneven mechanical loading. 
 
D) Circuit Overloading - Consideration should be given to the connection of the 
equipment to the supply circuit and the effect that overloading of the circuits might have 
on over current protection and supply wiring. Appropriate consideration of equipment 
nameplate ratings should be used when addressing this concern. 
 
E) Reliable earthing of rack-mounted equipment should be maintained. Particular 
attention should be given to supply connections other than direct connections to the 
branch circuit (e.g. use of power strips). 
 
F) Replacement of fuses should be only by qualified service personnel. 
 
G) A readily accessible disconnect device shall be incorporated in the building 
installation wiring.  
 
H) When connected to a 48 V centralized dc source, this product is to be installed only in 
Restricted Access Areas (Dedicated Equipment Rooms, Electrical Closets, or the like) 
and shall be provided with a Listed 5 A DC fuse or circuit breaker in the supply circuit. 
 
 
This section describes installation of the Magnum 6K8-Series Switches, as well 
as connection of the various Ethernet media types. 
 
3.1 
Locating Magnum 6K8-Series Switches 
 
For vertical panel mounting and wall mounting, see Section 3.4. 
 
For vertical DIN-Rail mounting, see Section 3.3. 
 
For DC power options, see Appendix B.  For Dual Source, see Appendix C.