GarrettCom 6K8 Manual De Usuario

Descargar
Página de 69
Magnum 6K8-Series Industrial Field Switch             Installation and User Guide   03/06) 
 
27
www  GarrettCom  com
.
.
 
Fig 3.3 - Magnum 6K8 mounted 
vertically with DIN-Rail brackets and 
latches 
The DIN-Rail mounting brackets 
and latches are optional and need to be 
ordered as separate items, e.g Model # DIN-
RAIL-6K8 
3.3.1 Installing 
DIN-RAIL 
variable brackets on 
Magnum 6K8 
Magnum 6K8 Din-Rail kit comes along 
with the following-
BOM: 
Item 
Quantity     Description 
    DIN Rail Clip assy 
    #10-32 x ¼ Phillip  
 
    Flat head screws with 
undercut 
    #4-40 x 3/8 Phillip Flat head screw 
 
Din-Rail kit Installation procedures: 
 
1. Remove the back plate from Magnum 6K8 UNIT 
a. There are eight screws along the edge of  the unit to remove. 
b.. Do not re-use the old screws. 
 
2. On the back-plate 
a. Locate the indented side with 1, 11…… 
b. “1” indentation signify center of the mounted Din-Rail clip  
location.
 
c. Each indented locations (1-11-111…) are ½ inches apart from the center. 
 
 
Fig 1. 
 
3. 
Select the height position via 
indented side marking .
 
 
4. Place the 
DIN Rail Clip 
assembly under indented side of 
the plate. Place two of the screws, 
came along the kit (#10-32 x ¼ 
Phillip Flat head screws with 
undercut) onto the indented side 
and screw tight the assembly as 
shown in Fig 2a.  
Note: Make sure the screws must 
have the 5lbs/in torque minimum.