GarrettCom 6K8 Manual De Usuario

Descargar
Página de 69
Magnum 6K8-Series Industrial Field Switch             Installation and User Guide   03/06) 
 
32
www  GarrettCom  com
.
.
referred to as “6KPMV” for convenience in describing port module installation. 
Magnum 6K8-Series Switches are normally received from the factory with all 
required 6KPMV modules installed. There may be situations where 6KPMV cards need 
to be added or replaced.  In cases where additional 6KPMV cards are needed, the 
faceplate for an available front-mounted slot must be removed. The following procedure 
describes this operation. The pictorial view of the hardware assembly can be seen here- 
http://www.garrettcom.com/Pictorial/6k8_pictorial.pdf
 
 
3.6.1 Preparation for Installing and Removing 6KPMVs from 6K8’s 
 
STOP!!!
 
Be sure the power cord is unplugged 
from the chassis before attempting to remove 
and/or replace any PM cards. 
Failure to do so may result in damage to the unit 
and will void the warranty.
 
Caution- Avoid Static Discharge:   The port modules (like most electronic 
equipment) are sensitive to static discharge.  Use proper ESD measures when 
handling port modules. 
 
Step 1.  Make sure the 6KPMV Card package has all necessary accessories and use the 
proper tool to install it properly. Each 6KPMV Card package, for field 
installation contains (Daughterboard (Bigger) and Granddaughter board 
(smaller), three 5/8 stand offs for Granddaughter board, 6 standoff for daughter 
Board, nine  #4-40x3/8 Pan-Head screws along with Front panel face plate 
package.  
NOTE: Every 6KPMV Card package comes with their matching Daughter and 
Granddaughter board. The copper 6KPMV card should not work properly if mixed 
with other Fiber combo 6KPMV card packages. Always install the PM module 
separately one by one to avoid the mixing.  
Do not change the Blue color DIP Switch setting ever! Leave it at factory default. 
Step 2.  Remove Chassis Cover