Magnum 6K16-Series Managed Fiber Switch Installation and User Guide (04/06)
 
 
33
www  GarrettCom  com
.
.
failure of the power supply inside of the Magnum 6K16 Switch. Useful info. about 
Alarm contacts:  
1. There is four terminal block (1,2,3,4)provided next to AC/DC power supply  
2. The top two pins (1,2) are software operated 
3. The bottom two pins (3,4) are hardware     operated 
4. By default it is NC (normally closed) 
5. The software operation need to be enable and set to get the Alarm traps. For detail 
information about the Software Alarm and software control of SNMP alarm traps, please 
reference the Magnum MNS-6K Software User Manual. (Chapter 19th). 
The Alarm Contacts are on the front left area (next to the DC power source) 
of the Magnum 6K16-Series unit and is green in color as shown in the picture. 
 
 
 
3.6  
6K16-Series Port Module (6KPM) Installation 
Note:  the modules used in the 6K16-Series vertical mount unit are similar to 
those used in rack-mount 6K units, except that the top LEDs are positioned for front 
viewing for the vertical-mount 6K16-Series model.  The modules have the letter  “V” in 
the model numbers, but otherwise are the same.  In the Port Module materials below, all 
modules are referred to as “6KPM” for convenience in describing port module 
installation. 
Magnum 6K16-Series Switches are normally received from the factory with all 
required 6KPM modules installed. There may be situations where 6KPM cards need to 
be added or replaced.  In cases where additional 6KPM cards are needed, the faceplate 
for an available front-mounted slot must be removed. The following procedure describes 
this operation. 
3.6.1  Preparation for Installing and Removing 6KPMs 
 
STOP!!!
 
Be sure the power cord is unplugged 
from the chassis before attempting to remove 
and/or replace any PM cards. 
Failure to do so may result in damage to the unit 
and will void the warranty.
 
Caution- Avoid Static Discharge:   The port modules (like most electronic 
equipment) are sensitive to static discharge.  Use proper ESD measures when 
handling port modules. 
 
Step 1.  Make sure the 6KPM Card package has all necessary accessories to install it 
properly. Each 6KPM Card package except the Gigabit, for field installation