GarrettCom P62-Series Manual De Usuario
Magnum P62-Series Hardened Switches Installation and User Guide (08/03)
27
www GarrettCom com
.
.
to be in contact with a vertical surface (such as pedestal) that has good heat conducting
properties. Remove rubber “feet”, if present, to enhance metal-to-metal contact and provide the
best heat transfer away from the PSX unit.
properties. Remove rubber “feet”, if present, to enhance metal-to-metal contact and provide the
best heat transfer away from the PSX unit.
UL Requirements
The following must be adhered to in order to conform to UL requirements:
6. Minimum 18 AWG cable for connection to a Centralized DC power source.
7. Minimum 14 AWG cable for connection to earthing wiring.
8. Use only with Listed 10 A circuit breaker provided in building installation.
9. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or
7. Minimum 14 AWG cable for connection to earthing wiring.
8. Use only with Listed 10 A circuit breaker provided in building installation.
9. “Complies with FDA radiation performance standards, 21 CFR subchapter J.” or
equivalent.
10. Fastening torque of the lugs on the terminal block: 9 inch pound max.
Centralized DC Power Source cable securement, use at least four cable ties to secure the
cable to the rack at least 4 inches apart with the first one located within 6 inches of the
terminal block.
Centralized DC Power Source cable securement, use at least four cable ties to secure the
cable to the rack at least 4 inches apart with the first one located within 6 inches of the
terminal block.
3.4
Cable Strain Relief Feature on all P62-Series models
The Magnum P62-Series Hardened Switches are designed to use in extended
temperature environments, which qualifying them to be used in roadside traffic data collection
and control stations, above-the-ceiling locations in commercial buildings, etc. They are usually
mounted vertically so that the cables hang out the bottom. There is a cable strain relief feature
provided as part of the package design
The Magnum P62-Series Hardened Switches have a tie wrap holder as part of the base
plate of the unit for cable strain relief. The strain-relief feature is applicable to power cables as
well as to Ethernet cables,
both twisted-pair copper and
fiber. Cable tie-wraps can
secure the cables and can be
attached to the base plate
HOOK provided at the
bottom-front of the unit. In the
event that the attached cable is
pulled, the tie-wrap cable
strain relief feature protects
the cable connection from
coming loose. This feature
provides a more reliable and robust installation and operation.
The figure above of a P62F model illustrates the strain-relief feature, using tie-wraps.