GarrettCom P62-Series Manual De Usuario

Descargar
Página de 37
Magnum P62-Series Hardened Switches                               Installation and User Guide (08/03)
2
www  GarrettCom  com
.
.
Rev A 04/01: This revision is the initial release of the P62F Hardened Switches user manual.
1.0
SPECIFICATIONS
1.1
Technical Specifications
Ports Performance 
 
       Fiber, and when an auto-negotiating port is operating at 100Mbps:
                            Data Rate: 100Mbps
       When an RJ-45 auto-negotiating port is operating at 10 Mbps:
                            Data Rate: 10 Mbps
        For mP62 models, RJ-45 ports are S/W controlled for speed and F/H
duplex, crossover (MDI – MDIX) is automatically handled
        
Network Standards
100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX
10 Mb:   Ethernet IEEE 802.3, 10BASE-T
Auto-sensing for speed: IEEE 802.3u; 802.3x flow control
For managed  mP62 models, IEEE 802.1p QoS and 802.1d Spanning Tree
For mP62 management software, see Section 2.2.3
               Packet-Processing Between Domains is non-blocking
       Filtering and Forwarding Rate from 100Mbps ports: 148,800 pps max 
Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.
Processing type: Store and Forward
Auto-learning:  4K address table (16K on P62F), shared for all ports
Packet buffers: 256KB, dynamically shared on all domains
Latency (not including packet time):   100 to 10 Mbps: 5
µ
10 to 100Mbps: 5
µ
s
Path Delay Value: 50 BT on all ports
Maximum Ethernet Segment (or Domain) Lengths
10BASE-T (Unshielded twisted pair)
 - 100 m (328 ft)
100BASE-TX (CAT 5 UTP)
 - 100 m (328 ft)
100BASE-FX, full-duplex: (multi-mode)
 - 2.0 km (6,562 ft)
        100BASE-FX, full-duplex: (single-mode)
 - 20.0 km (65,620 ft)
        100BASE-FX, full-duplex: (single-mode, long)  - 40.0 km (131,240 ft)
Operating Environment
Ambient Temperature:  -40
°F to 170°F for mP62 (160°F for P62F)   
(-40
°C to 75°C for mP62, 70°C for P62F))
Cold start down to -20
°C
Storage Temperature:  -40
° to 185°F  (-40°C to 85°C)
Ambient Relative Humidity:  5% to 95% (non-condensing)
Altitude:  -200 to 50,00 ft. (-60 to 15,000m)
“Plenum rated” for above-the-ceiling installation in office areas
IEC 529 rated IP51 (holds out dust, vertical water)
Operating Shock and Vibration: Meets Bellcore GR-63-CORE