Stackable Personal Hubs 
 Installation and User Guide   (04/01)
 
 
17
 
www  GarrettCom  com
.
.
 
When stacking, switch the 
Stack Enable switch of the bottom 
ST80 to the “OFF” position (left).  All 
other units should be switched to the 
“ON” position (right).  Using the IRB 
ribbon cable, connect one end to     
 
Two stacked ST80s - 16 RJ-45 ports 
either Inter-Repeater-Bus connector 
(IRB1 or IRB2)  of the bottom ST80.  
Connect the other end of the cable to 
the corresponding IRB connector of 
the top ST80 (i.e., the IRB cable is 
connected from IRB1 to IRB1, or from 
IRB2 to IRB2).  If additional ST80 
              Three stacked ST80s - 24 RJ-45 ports 
 Personal Hubs are to be added, 
connect another IRB cable from the 
unused IRB connector of the existing 
stack’s top unit to the corresponding 
IRB connector of the ST80 Personal 
Hub to be added.  Be sure that the 
Stack Enable Switch of the added unit 
is set to the “ON” position.  Up to five   
Four stacked ST80s - 32 RJ-45 ports 
Stackable Personal Hubs may be 
connected in this fashion.   
 
Each unit of the stack must be 
powered by its own external power 
supply unit.  “Power on” is verified by 
observing that the PWR LED of each 
unit is illuminated.  Should one unit of 
the stack be powered down, the 
remainder of the stack will still function  
Five stacked ST80s - 40 RJ-45 ports 
properly.   
 
 
 
Increased port capacity via stacking 
Magnum ST80 Stackable Personal Hub
Ports         1               2                3               4                5              6                7                 8
PWR                                    AUI
IR
B1
 IR
B
2
Stac
k E
nab
le
OF
F  
     
 O
N
UP-LINK
 
Magnum ST80 Stackable Personal Hub
Ports         1               2                3               4                5              6                7                 8
PWR                                    AUI
IR
B1
 IR
B
2
St
ac
k E
na
ble
OF
F  
     
 O
N
UP-LINK
 
Magnum ST80 Stackable Personal Hub
Ports         1               2                3               4                5              6                7                 8
PWR                                    AUI
IR
B1
 IR
B
2
St
ac
k E
nab
le
O
FF 
     
  ON
UP-LINK
 
Magnum ST80 Stackable Personsal Hub
Ports         1               2                3               4                5              6                7                 8
PWR                                    AUI
UP-LINK
Magnum ST80 Stackable Personal Hub
Ports         1               2                3               4                5              6                7                 8
PWR                                    AUI
IR
B1
 IR
B2
Sta
ck
 E
na
ble
O
FF
    
    
O
N
UP-LINK