4.4 Hardware operated Alarm Contact for monitoring internal power supply 
 
The two screws Alarm Contacts feature, standard on Magnum ES42H and P, 
provides Normally Closed (NC) contacts to which the user can attach one sets of status 
monitoring wires at the green terminal block. When this option is present, the terminal 
block for Alarm Contacts is part of the Power Input panel in the Magnum ES42s case. The 
DC power input connection is in the same panel.  
The NC Alarm Contact is held close 
when there is power on the main board inside of the 
ES42.  This provides a “Hardware operated Alarm” 
because the NC contacts will open when internal 
power is lost, either from an external power down 
condition or by the failure of the power supply inside 
of the Magnum ES42 Switch.  
Useful info about Alarm Contacts in 
ES42H and ES42P:  
 