GarrettCom 4K-Series Manual De Usuario

Descargar
Página de 45
Magnum 4K8 Switches      Installation and User Guide      (10/04) 
 
16 
www  GarrettCom  com
.
.
 
3.2.2 
Connecting Fiber Optic SC-type, "Snap-In" 
 
The following procedure applies to installations using a FPM with SC-type 
fiber connectors, i.e., using FPM-MSC, FPM-SSC single-mode, and FPM10-MSC. 
 
When connecting fiber media to SC connectors, simply snap on the two square 
male connectors into the SC female jacks of the FPM until it clicks and secures. 
 
3.2.3 Connecting 
Single-Mode Fiber Optic 
When using single-mode fiber cable, be sure to use single-mode fiber port 
connectors.  Single-mode fiber cable has a smaller diameter than multi-mode fiber cable 
(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx 
are the diameters of the core and the core plus the cladding respectively). Single-mode 
fiber allows full bandwidth at longer distances, and may be used to connect 10 Mb nodes 
up to 10 Km apart, or 18Km with the FPM-SSC. 
The same procedures as for multi-mode fiber applies to single-mode fiber 
connectors.  Follow the steps listed in Section 3.2.2 above. 
 
3.2.4 
Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or 
Shielded) 
The RJ-45 ports of the Magnum 4K-Series can be connected to the following 
two media types: 100BASE-TX and 10BASE-T.  CAT 5 cables should be used when 
making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 
may be used.  In either case, the maximum distance for unshielded twisted pair cabling is 
100 meters (328 ft). 
Media 
               
IEEE Standard          Connector  
Twisted Pair (CAT 3, 4, 5)                  10BASE-T                  RJ-45 
          
Twisted Pair (CAT 5)  
 100BASE-TX                RJ-45            
 
NOTE :   It is recommended that high quality CAT. 5 cables (which work for both 10 Mb 
and 100Mb) be used whenever possible in order to provide flexibility in a 
mixed-speed network, since dual-speed ports are auto-sensing for either 10 and 
100Mb/s.
  
  The following procedure describes how to connect a 10BASE-T or 100BASE-
TX twisted pair segment to the RJ-45 port. The procedure is the same for both 
unshielded and shielded twisted pair cables. 
1.    Using standard twisted pair media, insert either end of the cable with an RJ-45 
plug into the RJ-45 connector of the port. Note that, even though the connector is 
shielded, either unshielded or shielded cables and wiring may be used.