4.8 
Power Budget Calculations for 4K-Series FPM’s with Fiber Media 
 
 
Receiver Sensitivity and Transmitter Power are the parameters necessary to 
compute the power budget. To calculate the power budget of different fiber media 
installations using Magnum products, the following equations should be used: 
OPB (Optical Power Budget) = P
T
(min) - P
R
(min) 
      
 where P
= Transmitter Output Power, and P
R
 = Receiver Sensitivity 
   Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) 
   Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] 
 
where the “Cable Loss” for 62.5/125 and 50/125
µm
 (M.m) is 2.8 dB/km,  
 
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, 
 
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km 
 
The following data has been collected from component manufacturer’s (Agilent’s and 
Siemens’) web sites and catalogs to provide guidance to network designers and installers. 
Fiber  
Port 
Module 
Speed,  
 
Std. 
 
Mode
Std. 
km  
fdx 
(hdx) 
Wave
-
length
nm 
Cable 
Size 
µ
X’mitr 
Output 
P
T ,
 dB
R’cvr 
Sens.
P
R ,
dB
Worst 
OPB,
dB 
Worst* 
distance 
Km, fdx
typical
OPB,
dB 
typical* 
distance 
Km, fdx 
FPM10-
FST 
10 Mb 
FL 
Multi-
mode
(2) 
 
 
850 
62.5/125
100/140
50/125
-15.0 
-9.5 
-19.5 
-31 
-31 
-31 
14 
19.5 
9.5   
5.9 
3.4 
17 
23.5 
13.5 

4.8 
 
FPM10- 
SST 
10 Mb 
FL 
Single-
mode
10 
(5) 
1300
9/125 -30 -39 7 
14 
13  26 
FPM- 
MST, MSC 
100Mb 
FX 
Multi-
mode
(0.4) 
1300
62.5/125
50/125
-20 
-23.5 
-31 
-31 
9.0 
5.5 
2.5 
2.0 
14 
12 
4 
FPM-SSC 
100Mb 
FX 
Single-
mode
18+ 
(0.4)  1300
9/125 -15 -31 14  28 
17.5  35 
FPM-SSCL 
Long reach 
100MB 
FX 
single-
mode
40 
(0.4) 
1300
9/125 -5 -34 27  54  32.5  65 
FPM- 
MTRJ 
100Mb 
FX 
Multi-
mode
(0.4) 
1300
62.5/125
50/125
-20 
-23.5 
-31 
-31 
9.0 
5.5 
3.0 
2.0 
15.8 
12.2 
5.5 
4.0 
 
* Not
e:  The use of either multi-mode or single-mode fiber to operate at 100Mbps speed 
over long distances (i.e., in excess of  approx. 400 meters) can be achieved 
only
 
if the following factors are both applied: 
• 
The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the 
full-duplex (factory default) setting for 100Mbps fiber ports must be used, 
and 
• 
The worst-case OPB of the fiber link must be greater than the fiber cable’s 
passive Attenuation. 
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)