GarrettCom DS8016 Manual De Usuario

Descargar
Página de 42
Magnum DS8016 Dual-Speed Stackable Hubs        Installation and User Guide (07/06) 
 
 
15 
www  GarrettCom  com
.
.
 
 
3.0 
Magnum DS8016 Installation 
 
Before installing the equipment, it is necessary to take the 
following precautions: 
1.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, the environmental temperature around the equipment must 
be less than or equal to 50
0
C. 
2.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, adequate air flow must be maintained for proper and safe 
operation. 
3.) 
If the equipment is mounted in an enclosed or multiple rack 
system placement of the equipment must not overload or load 
unevenly the rack system. 
4.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, verify the equipment’s power requirements to prevent 
overloading of the building/s electrical circuits. 
5.)  
If the equipment is mounted in an enclosed or multiple rack 
assembly verify that the equipment has a reliable and uncompromised 
earthing path.
 
6.)  
If the intra-building wiring (cabling) is involved with this 
product(NEBS), then it is recommended to have shielded cable and 
the shield is grounded at both ends.
 
7.) 
This equipment is for installation only in a Restricted Access 
Location (dedicated equipment room service closet and the like) in 
accordance with the National Electrical code. 
 
 
 
Installation: This chapter provides instructions for installing the Magnum DS8016 hubs. 
3.1 
Locating Magnum DS8016 Dual-Speed Hubs 
 
The location of a Magnum DS8016 Dual-Speed Hub is dependent on the physical 
layout of the network.  Typically the hub is placed where combinations of 10Mb and 100Mb 
network devices need to be connected to communicate with each other.  The 19” rack width 
size of the unit allows it to be conveniently placed in a wiring closet, an office or a lab area, 
and it can also be either shelf- or rack-mounted.  (See instructions in 3.1.2 below).  Rack-
mounting brackets are included with each unit.  
 
Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum 
DS8016 site.  The rugged metal case of the Magnum DS8016 will normally protect it from 
accidental damage in a lab or workplace setting.  Maintain an open view of the front to 
visually monitor the status LEDs.  Keep an open area around the unit so that cooling can 
occur from the small fan on the left side while the unit is in operation. 
3.1.1 
Table-Top or Shelf Mounting 
 
The Magnum DS8016 Dual-Speed Hub can be easily mounted on a table-top or 
any suitable horizontal surface, and has four rubber feet to provide stability without 
scratching finished surfaces.