GarrettCom DS8016 Manual De Usuario

Descargar
Página de 42
Magnum DS8016 Dual-Speed Stackable Hubs        Installation and User Guide (07/06) 
 
 
26 
www  GarrettCom  com
.
.
 
4.3          LED’s 
 
PWR  
:   Illuminates GREEN to indicate AC power is applied to the unit. 
 
   
COL  
:  Red LED Blinks intermittently when a collision occurs. 
 
 BR              :   Bridge Module Indicator, On when 10/100 bridge module is 
installed  (Model DS8016-B), Off when no bridge module is inside  
(DS8016A) 
 
 
                100/Auto    :  Speed LED per port.  Steady On when speed is 100Mbps , Off when 
speed is 10Mb, flashing when auto-negotiating or when not 
connected (no LINK) 
                 LK/RX      :  Activity LED per port. Steady On when twisted-pair link is  
 
 
 
  operational.  Activity, flashing when port is receiving data. 
 
 
 
 
4.4 
Up-link  Port 1X 
 
Magnum DS8016s each have one Up-link port, port # 1X, which can be used 
when port #1 is not connected. The Up-link port allows repeater-to-repeater connections 
without a special cross-over cable.  It works the same for 10Mb or 100Mb connections.   
Use port “1”  (or ports 2 thru 16) for straight-through twisted pair cabling from 
the DS8016 port to a user device, or the “1X”  port for cross-over or up-link segment 
connections from the first DS8016 port to a repeater or hub or switch. Verify proper port 
connection by noting the port’s LINK/RX status, which is illuminated when a proper link 
is made and blinking when there is activity.  
 
Note: Port # 1 and Port # 1X, provided for RJ45 connections, are logically one port. 
Only one of these ports, either # 1 or # 1X may be used at one time simultaneously.