GarrettCom DS8016 Manual De Usuario

Descargar
Página de 42
Magnum DS8016 Dual-Speed Stackable Hubs        Installation and User Guide (07/06) 
 
 
32 
www  GarrettCom  com
.
.
 
 
 
APPENDIX C: Optional 48V Dual-Source DC Power, Addendum 
 
C1.0 
SPECIFICATIONS - FOR MAGNUM DS8016 DUAL-SPEED HUBS 
 
 
Power Supply (Internal,  48VDC Dual-Source model) 
 
  DC Power Connector:  First Source: “A+”, “A
-“
, 2nd Source “B
-
“, “B+”  
 
  GND:  Terminal for “earth” or ground wire connection to the hub chassis 
 
  Input:      Two separate sources, each at 36 - 70 VDC (auto-ranging) 
 
  Power Consumption:     Model DS8016: 25 watt typical, 40 watts max. 
 
   
                     
 
 
With the exception of the dual DC input power connections and the power supply, all 
specifications and configuration options for the Magnum DS8016-48VDC with this Dual-
Source option are identical to those listed in the Magnum DS8016 Dual-Speed Hubs 
Installation and User Guide
, including Appendix A “Optional 48VDC Power”  
  
C2.0 
MAGNUM DS8016  (48VDC DUAL-SOURCE POWER OPTION) 
 
The hub models with the internal 48VDC Dual-Source power supply are designed 
for installations where a battery plant is the power source, and where two separate power 
sources are utilized in order to increase operational uptime and to simplify maintenance.   
The functionality of the Magnum DS8016-48VDC Dual-Source Option hubs are 
identical to the standard AC-powered models.  All Port Module, SNMP and stacking options 
are available for configuration with Dual-Source Option units.  Refer to the main sections of 
this Installation and User Guide for a detailed description of the Magnum DS8016 Hubs. 
C3.0 
DUAL-SOURCE OPTION, THEORY OF OPERATION 
 
The Dual-Source DC power option is designed using diodes inside of the hub on 
each DC power input line.  A diode is placed 
in each of the four input lines (behind the 
four external power connection terminals) so 
that power from an external source can only 
flow into the hub.  This allows the hub to 
operate whenever DC power is correctly 
applied to either or both of the two inputs. 
GND
FUSE
+
-
SUPPLY
A+
A-
B-
B+
GND
CHASSIS
HUB