GarrettCom 6K32T Manual De Usuario

Descargar
Página de 78
Magnum 6K32T & 6K32TRC Managed Switch          Installation and User Guide 05/07) 
 
 
4
 
 
www  GarrettCom  com
.
.
Fuse Required – 2Amps 
 24VDC Power Input Voltage : 20 to 40VDC 
Fuse Required – 3Amps 
125VDC Power and 100VDC Input Voltage : 88 to 300VDC 
Fuse Required – 1Amps 
Std. Terminal Block :   “ -, GND, + ” 
Power Consumption: same as for AC models, see above 
Warning- All the fuse replacment must be replaced with same value. 
For (Optional) DC internal power supplies at –48VDC, 24VDC and 125VDC, 
including Dual Source options (
for continuity of operation when either of the DC 
input sources are interrupted)
, see Appendices B and C. 
 Cooling 
Method- 
 
6K32T/ 6K32TR(Reverse)- Fan cooled (3 fans inside) 
 
6K32TRC-  Convection cooled (No fans) Static Thermal design techniques 
 
Relay Alarm Contact (Optional) 
The Alarm Contact option is offered as a configuration option.
 
The alarms can be 
initiated through two normally closed Form-C contacts, one loss of power alarm 
and one software alarm through user selectable software traps. 
 
Per-port MDI or MDIX on RJ-45 
 
 
The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45 
ports., and eliminate the use of cross-over cable between the devices. Also 
port-specific user settings (such as FDX or HDX, copper 10/100 speed) can 
be fixed using software commands. 
 
 
 
 Agency 
Approvals 
 
 
UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15, Class A 
 
 
NEBS L3 and ETSI Compliant, NEMA TS-2 for traffic control 
 
 
IEEE 1613 Environmental Standard for Electric Power Substations. 
                      See also Note for Power Substations in Section 3.2.4, 3.6.1, and 5.2.9 
 
 
IEC61850 EMC and Operating Conditions Class C for Power Substations 
 
 
 
 Warranty: 
Three years, return to factory   
Made in USA 
 
 
For a Configuration Guide, see the GarrettCom web site at 
http://www.garrettcom.com/techsupport/insertion_guides/6k32trcg.pdf
    (6K32) 
http://www.garrettcom.com/techsupport/insertion_guides/6k32trccg.pdf
    
(6K32TRC) 
Email 
mktg@GarrettCom.com
 for additional details.