GarrettCom P62 Manual De Usuario

Descargar
Página de 40
Magnum P62-Series Hardened Switches                               Installation and User Guide (11/03)
 
 
 
22 
 
3.2 
Connecting Ethernet Media, and Special Strain-relief feature 
         
Note – see also “Cable Strain Relief Feature, Section 3.4. 
The Magnum P62-Series Ethernet Switches (P62F model illustrated here) can be 
connected to the following three 
media types: 100BASE-TX, 
10BASE-T and 100BASE-FX.  
CAT 5 cables should be used when 
making 100BASE-TX connections. 
When the ports are used as 
10BASE-T ports, CAT 3 may be 
used.  In either case, the maximum 
distance for unshielded twisted pair 
cabling is 100 meters (328 ft). For 
fiber port 100BASE-FX multi-
mode, 50/125 or 62.5/125 microns 
cabling can be used, whereas for single-mode, 9/125 microns cabling should be used. Fiber 
cabling supports much longer cable distances and higher bandwidth than copper wiring. 
 
Media 
               
IEEE Standard          Connector  
Twisted Pair (CAT 3 or 5)                  10BASE-T                  RJ-45 
          
Twisted Pair (CAT 5)  
 100BASE-TX                RJ-45            
Fiber (Multi-mode) 
 100BASE-FX  
SC 
Fiber (Single-mode) 
 100BASE-FX  
SC 
 
NOTE 1. :   It is recommended that high quality CAT. 5 cables (which work for both 10 Mbps 
and 100Mbps) be used whenever possible in order to provide flexibility in a mixed-
speed network, since P80-series switch ports are auto-sensing for either 10 and 
100Mbps.  Note that the auto-sensing function does not sense the cable type.  
 
 
 3.2.1 
Connect Twist Pair  (RJ-45, CAT 3 or CAT 5, Unshielded or Shield) 
The following procedure describes how to connect a 10BASE-T or 100BASE-TX   
twisted pair segment to the RJ-45 port.  The procedure is the same for both unshielded 
and shielded twisted pair cables. 
 
 
www  GarrettCom  com
.
.