GarrettCom P62 Manual De Usuario

Descargar
Página de 40
Magnum P62-Series Hardened Switches                               Installation and User Guide (11/03)
 
 
 
28 
to be in contact with a vertical surface (such as pedestal) that has good heat conducting 
properties. Remove rubber “feet”, if present, to enhance metal-to-metal contact and provide the 
best heat transfer away from the PSX unit.
 
 
 UL Requirements 
 
The following must be adhered to in order to conform to UL requirements: 
6.   Minimum 18 AWG cable for connection to a Centralized DC power source. 
7.   Minimum 14 AWG cable for connection to earthing wiring. 
8.   Use only with Listed 10 A circuit breaker provided in building installation. 
9.   
“Complies with FDA radiation performance standards, 21 CFR subchapter J.” or 
equivalent. 
10.   Fastening torque of the lugs on the terminal block:  9 inch pound max. 
Centralized DC Power Source cable securement, use at least four cable ties to secure the 
cable to the rack at least 4 inches apart with the first one located within 6 inches of the 
terminal block. 
 
3.4 
Cable Strain Relief Feature on all P62-Series models 
 
The Magnum P62-Series Hardened Switches are designed to use in extended 
temperature environments, which qualifying them to be used in roadside traffic data collection 
and control stations, above-the-ceiling locations in commercial buildings, etc. They are usually 
mounted vertically so that the cables hang out the bottom. There is a cable strain relief feature 
provided as part of the package design  
The Magnum P62-Series Hardened Switches have a tie wrap holder as part of the base 
plate of the unit for cable strain relief. The strain-relief feature is applicable to power cables as 
well as to Ethernet cables, both 
twisted-pair copper and fiber. 
Cable tie-wraps can secure the 
cables and can be attached to 
the base plate HOOK provided 
at the bottom-front of the unit. 
In the event that the attached 
cable is pulled, the tie-wrap 
cable strain relief feature 
protects the cable connection 
from coming loose. This feature 
provides a more reliable and 
robust installation and operation. 
 
The figure above of a P62F model illustrates the strain-relief feature, using tie-wraps. 
www  GarrettCom  com
.
.