1.0 SPECIFICATIONS 
1.1 Technical 
Specifications 
 
Ports Performance  
 
 
       Fiber, and when an auto-negotiating port is operating at 100Mbps: 
                            Data Rate: 100Mbps 
 
       When an RJ-45 auto-negotiating port is operating at 10 Mbps: 
                            Data Rate: 10 Mbps 
 
        For mP62 models, RJ-45 ports are S/W controlled for speed and F/H 
duplex, crossover (MDI – MDIX) is automatically handled
 
         
 
Network Standards 
 
100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 
 
10 Mb:   Ethernet IEEE 802.3, 10BASE-T 
 
Auto-sensing for speed: IEEE 802.3u; 802.3x flow control 
 
For managed  mP62 models, IEEE 802.1p QoS and 802.1d Spanning Tree 
 
For mP62 management software, see Section 2.2.3 
               Packet-Processing Between Domains is non-blocking 
 
       Filtering and Forwarding Rate from 100Mbps ports: 148,800 pps max  
 
Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max. 
 
Processing type: Store and Forward 
 
Auto-learning:  4K address table (16K on P62F), shared for all ports 
 
Packet buffers: 256KB, dynamically shared on all domains 
 
Latency (not including packet time):    100 to 10 Mbps:  5
µ
s  
 
 
    10 
to 
100Mbps: 
5
µ
 
Path Delay Value: 50 BT on all ports
 
 
 
 
 
Maximum Ethernet Segment (or Domain) Lengths 
 
10BASE-T (Unshielded twisted pair) 
 - 100 m (328 ft)   
 
100BASE-TX (CAT 5 UTP) 
 
 - 100 m (328 ft)
 
 
 
100BASE-FX, full-duplex: (multi-mode) 
 - 2.0 km (6,562 ft) 
 
        100BASE-FX, full-duplex: (single-mode) 
 - 20.0 km (65,620 ft) 
 
        100BASE-FX, full-duplex: (single-mode, long)   - 40.0 km (131,240 ft) 
Operating Environment 
 
Ambient Temperature:  -40
°F to 170°F for mP62 (160°F for P62F)    
  
(-40
°C to 75°C for mP62, 70°C for P62F)) 
 
Cold start down to -20
°C 
 
Storage Temperature:  -40
° to 185°F  (-40°C to 85°C) 
 
Ambient Relative Humidity:  5% to 95% (non-condensing) 
 
Altitude:  -200 to 50,00 ft. (-60 to 15,000m) 
 
“Plenum rated” for above-the-ceiling installation in office areas 
 
IEC 529 rated IP51 (holds out dust, vertical water) 
www  GarrettCom  com
.
.