M A G N U M   6 K   S W I T C H E S ,     M N S - 6 K   U S E R   G U I D E  
 
Some of the parameters in the Magnum 6K family of switches are shown above. The 
list of parameters below indicates some of the key parameters on the switch and the 
recommendations for changing them (or optionally keeping them the same).
 
Privilege levels 
Two privilege levels are available - Manager and Operator. Operator is at privilege 
level 1 and the Manager is at privilege level 2 (the privilege increases with the levels). 
For example, to set up a user for basic monitoring capabilities use lower number or 
operator level privilege (Level 1) 
 
The Manager level provides all Operator level privileges plus the ability to 
perform system-level actions and configuration commands. To select this level, enter 
the ‘enable <user-name>’ command at the Operator level prompt and enter the 
Manager password, when prompted.  
Syntax enable <user-name> 
For example, switching from an Operator level to manager level, using the ‘enable’ 
command is shown below in Figure 6 
 
Magnum6K25> 
enable manager 
Password: ******* 
Magnum6K25#  
F
IGURE 
6
 
-
 Switching users and privilege levels. Note the prompt changes with the new privilege 
level.
 
Operator Privileges 
Operator privileges allow views of the current configurations but do not allow 
changes to the configuration.  A ">" character delimits the Operator-level prompt. 
Manager Privileges 
Manager privileges allow configuration changes. The changes can be done at the 
manager prompt or for global configuration as well as specific configuration. A “#” 
character delimits any Manager prompt.  
User management 
A maximum of five users can be added per switch. Users can be added, deleted or 
changed from a manager level account. There can be more than one manager 
account, subject to the maximum number of users on the switch being restricted to 
five.  
 