U P D A T I N G     S O F T W A R E   –   S T E P   3  
 
 
 
Upgrade is Successful.  Please reboot Magnum 6Kxx to start the application 
Magnum6K25# 
reboot
 
  Proceed on rebooting the switch? [ 'Y' or 'N' ] 
Y
 
Do you wish to save current configuration? [ 'Y' or 'N' ] 
Y 
 
(The switch will now reboot. After the reboot, the Magnum 6K switch may prompt you should the 
boot code need an update. If prompted, say “Y” to update the boot code. After the reboot and 
login verify the MNS-6K software was upgraded.) 
 
Magnum6K25# 
show version
 
   MNS-6K Ver: 3.4 Date:Mar 31 2006 Time:17:06:23 Build ID 1143853580 
F
IGURE 
155
 
– upgrading the switch using the serial interface 
Network Access 
Prerequisites - make sure the directory and the file name of the MNS-6K software image 
downloaded in steps 1 and 2 is known. To upgrade using TFTP or FTP, ensure that the 
FTP or TFTP server is set up and the switch can ‘ping’ the TFTP or the FTP server and 
vice-versa. Ensure that the server has access to the MNS-6K software image downloaded in 
step 2. Make sure the MNS-6K software image file is copied to the default folder specified 
by the FTP or TFTP server. If using FTP services, make sure the FTP access information 
(login name and password) is also known. 
In the example below, let us assume that the IP address of the TFTP server is 
192.168.10.99; that the server can ping the switch and the switch can ping the server.  
 
 
 
 
Intentionally left blank for image continuity – image shown on next page 
 
 
 