Fujitsu FD-1016AT Manual De Usuario

Descargar
Página de 44
 
14 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5. In the case of a cascaded connection (when KVM Switch is connected in a 
two-level connection) 
By using cascaded connections (maximum 1 master and 8 slaves) it is possible to 
hook up a maximum of 64 servers. 
 
1) Connect the master switch device's ports one through eight to the second level of 
switch devices (called slaves), in the same way as for the [first level]. 
2) Next, use the special cables to attach the [keyboard/mouse] and [DISP] connector of 
the first level switching device (called master) to the [Keyboard], [Mouse], and 
[Console] connector on the console ports of the second level slave switch devices. 
3) To increase the number of slaves, connect them in the same way as described in 
steps 1 and 2 above. Do not connect slaves beyond the second level. Third level 
connection does not work. 
 
 
 
 
When the Console Drawer is used in a cascaded connection, the connector 
for the slave Console and for the master-side server can be connected 
using only the PS/2 special cable. Operation by a cable other than the 
special cable for the PS/2 cable will not be possible.