AIS-VHF data-link message, AIS-VHF data-link own-vessel message 
Where there is no commercial off-the-shelf interface available to obtain radar data then AIS target 
data shall be recorded as a source of information regarding other ships, otherwise AIS 
information may be recorded additionally as a beneficial secondary source of information on both 
other and own ship. 
 
The VDM message (UAIS VHF Data-link) shall be recorded in such a way that all target data 
available from the onboard AIS are acquired. If the VDO message (UAIS VHF Data-link 
Own-vessel report) is recorded, this shall be additional to the recording of individual sensor data. 
 
Depth (echo sounder) 
Depth under keel up to a resolution of 0.1 m as available on the ship is recorded. 
 
Alarms 
The status of all IMO mandatory alarms is recorded individually with ID number and time stamp.   
Audible alarms from the alarm units are stored simultaneously by the bridge audio microphones. 
 
Rudder order/response 
Rudder order and response angles are recorded up to a resolution of 1° as available on the ship. 
The rudder information is recorded. If more than one rudder is provided, the circuitry can be 
duplicated. 
 
Engine order/response 
The DCU obtains the engine order and response from the engine telegraph or direct engine 
control. The signal level is normally 0-10 V. The engine parameters with shaft revolution and 
ahead/astern indicators are recorded to a resolution of 1 rpm.   
 
All order and response from bow, stern, thruster, tunnel thrusters and controllable pitch propellers 
shall be recorded. The S-VDR shall record this data if said serial data is available. 
 
Hull openings, watertight doors 
Inputs digital or RS-422 serial can be connected individually. The data is received at intervals of 1 
s and stored with time stamps. Serial data sentence XDR is received at a data rate of 1,200-9,600 
baud. 
 
Accelerations and hull stresses 
The DCU obtains signals from appropriate hull stress and response monitoring devices. The 
inputs are recorded individually and stored with time stamps. Serial data sentence XDR is 
received at a data rate of 1,200-9,600 baud. 
 
Wind speed and direction 
The DCU obtains the signal from appropriate wind speed and direction sensor. The inputs are 
recorded individually and stored with time stamps. Serial data sentence XDR is received at a data 
rate of 1,200-9,600 baud. 
 
VDR alarm output 
There is no requirement for the S-VDR to send alarm messages. If, as an option, such messages 
are sent then the appropriate sentence format is ALR.