Brocade Communications Systems IPMC5000PEF Manual De Usuario

Descargar
Página de 230
Displaying MLD group information
To display the list of multicast groups, enter a command such as the following.
device #show ipv6 mld group
Total 2 groups
-------------------------------------------------------------------------------------
-
Idx  Group Address                            Port   Intf   GrpCmpV Mode    Timer 
Srcs
----+----------------------------------------+------+------+-------+-------+-----
+----
   1 ff05::4422                               e3/1/1  v170      Ver1 exclude   221   
0
   2 ff3f::300                                e3/1/1  v170      Ver2 include     0   
1
Total number of groups 2
Syntax: show ipv6 mld vrf vrf-name ] group
The vrf parameter allows you to display the list of IPv6 MLD groups for the VRF instance identified by
the vrf-name variable.
The following table displays the output from the show ipv6 mld group command.
Output from the show ipv6 mld group command 
TABLE 41   
Field
Description
IDX
Index for the MLD group.
Group Address
IPv6 address of the multicast group.
Port
The physical port to which the group belongs.
Intf
The routing interface to which the port belongs.
GrpCmpV
The version of the MLD group report message.
Mode
Indicates if the filter mode of the multicast group is in INCLUDE or EXCLUDE.
Timer
The number of seconds the interface can remain in its current mode.
Total number of groups
The total number of MLD groups.
Displaying MLD definitions for an interface
To display the MLD parameters on an interface, including the various timers, the current querying
router, and whether or not MLD is enabled, enter the following command.
Brocade#show ipv6 mld interface
---------+------+---------+---------------------------------------+--
Intf/Port|Groups| Version |   Querier      | Timer |V1Rtr| Tracking
      |   |Oper Cfg|             |OQrr GenQ| |
---------+------+----+----+---------------------------------------+--
e1/1/1         0        2      - Self     0      0     No  Disabled
v40            0        2      -                           Disabled
 e3/1/1        1        2      - Self     0      0     No
 e2/1/1        1        2      - Self     0      0     No
 e1/1/1        1        2      - Self     0      0     No
v50            0        2      -                           Disabled
Displaying MLD group information
202
FastIron Ethernet Switch IP Multicast Configuration Guide