220
Converged Enhanced Ethernet Command Reference
53-1001762-01
dot1x quiet-period
13
DRAFT: BROCADE CONFIDENTIAL
dot1x quiet-period
Sets the number of seconds that a switch remains quiet between a failed authentication and an 
attempt to retry authentication. 
Synopsis
dot1x quiet-period interval seconds
no dot1x quiet-period
Operands
interval seconds 
Specifies the time in seconds between attempts at authentication. The range 
of valid values is 1-65535.
Defaults
The default time is 60 seconds.
Command
Modes
Interface configuration mode
Description
Use this command to set the time in seconds after which a switch attempts to perform 
authentication after a failed authentication. Use the no dot1x quiet-period command to return to 
the default setting. When a switch cannot authenticate a client, the switch remains idle for a 
quiet-period interval of time, then attempts the operation again. 
Usage
Guidelines
Changing the quiet-period interval time to a number lower than the default can result in a faster 
response time.
Examples
To change the interval time to 200 seconds:
switch(config)#interface tengigabiethernet 0/1
switch(conf-if-te-0/1)#dot1x quiet-period 200