Brocade Communications Systems 2.1 Manual De Usuario

Descargar
Página de 44
4
Network OS Documentation Update
53-1002606-06
Chapter 23, Configuring LLDP
1
1. Log in to any switch in a Brocade VCS Fabric cluster.
2. In the global configuration mode, enter the interface command to select the RBridge/slot/port 
for which you want to enable edge-loop detection.
3. In the interface configuration mode, enter the edge-loop-detection vlan command to specify 
the VLAN you want ELD to monitor on this port.
If you do not specify a VLAN, the command fails.
4. Optional: Enter the edge-loop-detection port-priority command to specify the ELD port priority 
of the specified port for the selected VLAN. Enabling switching is not mandatory when 
assigning a port-priority.
Example 
This example sets the ELD port priority on two port/VLAN pairs: port 1/0/7 VLAN 10 and port 
4/0/6 VLAN 10. If both these ports are detected in the same loop, ELD shuts down port 4/0/6 
when the pdu-rx-limit for the Brocade VCS Fabric cluster is reached. Port 4/0/6 is chosen for shut 
down because it has been assigned the lower priority (higher number) then port 1/0/7.
(config)# interface TenGigabitEthernet  1/0/7 
(conf-if-te-1/0/7)# edge-loop-detection vlan 10 
(conf-if-te-1/0/7)# edge-loop-detection port-priority 5 
(conf-if-te-1/0/7)# top 
(config)# interface TenGigabitEthernet 4/0/6 
(conf-if-te-1/0/7)# edge-loop-detection vlan 10 
(conf-if-te-1/0/7)# edge-loop-detection port-priority 7 
Chapter 23, Configuring LLDP
Delete the section titled “DCBX interaction with other vendor devices” on page 274.