Switch discovery failure
During the setup of your switch, the switch discovery may fail. There may be several reasons why 
switch discovery fails. 
 lists symptoms and related suggestions to recover the switch.
Configuring the switch
The configuration wizard steps you through the process of changing your administrative password 
and zoning. You begin at the Welcome to Switch Configuration window (
).
TABLE 2
Discovery recovery
Symptom
Correction
For serial connections:
The setup computer COM port is busy.
The port is being controlled by another communications program. 
Stop all other third-party communications programs.
The port settings are in conflict with another device. Check your 
IRQ settings. 
On Windows systems:
By default, COM1 and COM3 use IRQ4, while COM2 and COM4 
use IRQ3. If another device is sharing the IRQ of the port, you 
must change the IRQ of the conflicting device. Hardware conflicts 
can also occur with the I/O address of the COM port. The 8514a 
video chip or its clones (S3 chip set) on some video cards create a 
conflict with COM4 because they use the same address of 02E8. 
The switch does not respond to 
commands during a serial connection.
The serial cable may not be connected properly between the 
setup computer and the switch. Check the serial cable to ensure 
it is secured.
The switch does not power up.
Verify that the switch’s power cable is securely plugged into a 
proper outlet and that the switch’s power button is turned on.
The switch’s serial adapter does not 
work.
Verify that the cable is good by replacing the cable or trying it on 
another known working device.
If the cable is good, then call your support provider for further 
instructions.
For Ethernet connections:
The WWN is not entered correctly.
Verify that the WWN is correct.
The target switch is not on the same 
subnet as the host.
Connect the host to the same subnet as the target switch. If it is 
not possible or convenient to do so, use the serial connection to 
set the IP address.
The target switch has no IP address 
instead of the factory default 
10.77.77.77.
Use the serial connection to set the IP address.
You have requested automatic address 
assignment in an environment where a 
DHCP server is not available.
Use the serial connection to set a reachable address.