Brocade 6910 Ethernet Access Switch MIB Reference
53-1002582-01
Examples
Examples
RMON event traps
The following is an example of how to generate an SNMP trap for an RMON event.
If you want to configure a device to send an SNMP trap when the number of broadcast packets 
exceeds 100, do the following:
1. Configure an RMON alarm with an ID of 1 that checks etherStatsBroadcastPkts for Port 1 every 
15 seconds to see if it exceeds a specified delta threshold (i.e., a change compared to the last 
reading). In every sample, check if etherStatsBroadcastPkts exceeds 100 packets compared to 
the last measurement. If it does, send an event (id 1) with “Tom” as the owner name. The event 
trigger is re-armed, when the falling-threshold value falls below 30 packets since the last 
reading.
Console(config)#rmon alarm 1 1.3.6.1.2.1.16.1.1.1.6.1 15 delta 
rising-threshold 100 1 falling-threshold 80 1 owner Tom
The rising and the falling thresholds are used for the presence and absence of one specific 
condition, with an oscillation buffer in between (e.g. warning versus no warning, not opposite 
events like “too much” and “too little”), and should be near each other to be meaningful. The 
data monitored may oscillate between these thresholds over time, triggering multiple events, 
e.g. when using the settings of 100 and 80 as in the preceding example.
snTrapStackingChasPwrSupplyFailed 
brcdIp.0.167
snChasUnitIndex,
snChasPwrSupplyIndex,
snAgGblTrapMessage
Minor
The SNMP trap that is generated 
when a power supply operational 
status changed from normal to 
failure for a stacking system.
Sample Trap Message
System: Stack unit 
<unitNumber>
Power supply
<snChasPwrSupplyIndex> is 
down
snTrapStackingTemperatureWarning
brcdIp.0.171
snChasUnitIndex, 
snAgGblTrapMessage
Critical
The SNMP trap that is generated 
when the actual temperature 
reading rises from the falling 
threshold and reaches the rising 
threshold.
Sample Trap Message
System: Stack unit 
<unitNumber> Temperature 
<actual-temp> C degrees, 
warning level 
<warning-temp> C degrees