CHAPTER 2: PRODUCT OVERVIEW
11
Figure 2-1.  Example of a ServSelect III Configuration
2.2  Safety Precautions
To avoid potential video and/or keyboard problems when using BLACK BOX products:
Ιf the building has 3-phase AC power, ensure that the computers and monitors are on 
the same phase. For best results, they should be on the same circuit.
Use only BLACK BOX-supplied cable to connect computers and KVM switches.
To avoid potentially fatal shock hazard and possible damage to equipment, please observe 
the following precautions:
Do not use a 2-wire extension cord in any BLACK BOX product configuration.
Test AC outlets at the computer and monitor for proper polarity
and grounding.
Use only with grounded outlets at both the computer and monitor. When using a 
backup Uninterruptible Power Supply (UPS), power the computer, the monitor and 
the ServSelect III off the supply.
NOTE: 
The AC inlet is the main disconnect.
SAMs
or ServSelect III 
cables
Analog 
Connection
Rack of Servers
ServSelect III
(KV22016A Shown)
Analog 
Connection
Critical server