Advanced Options
Advanced options are available only to the 
Admin user and consist of settings that are 
related to specialist areas such as power 
control and DDC.
Power Control
The options within this section are concerned with the operation of the 
POWER 
CONTROL
 port when used to command optional system power control units.  
Baud Rate
Settings: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 
Configures the communication speed of the 
POWER CONTROL
 port and must 
match the speed used by the connected power switche(s). Note: The PSE508SA 
and PSE508MA (not available in North America) power switches supplied by 
Black Box require a setting of 9600.
Format
Settings: NONE.8.1, ODD.8.1, EVEN.8.1, NONE.8.2, NONE.7.2, ODD.7.2, 
EVEN.7.2  
Configures the data format used by the serial port and must match the format 
used by the connected power switche(s). The NONE/ODD/EVEN portion relates 
to the parity checking; the 7/8 value is the size of the data byte and the 1/2 
value determines the stop bit(s) used after each data byte.
SERVSWITCH CX
Advanced Options
DDC Options
Power Control
Enter-Select
F1-More menus
Esc-Quit
Firmware Version 1.02
DDC Options
The options within this section are related to the Display Data Channel features 
supported by the ServSwitch CX. DDC is an industry standard format that allows 
server systems to be informed of the capabilities of the video monitor connected 
to them.
DDC Source
Settings: AUTO, LOCAL, DEFAULT
Determines which user port monitor should be interrogated to discover its 
capabilities. AUTO begins with the local user port and if it fails, it uses a set of 
default values. The LOCAL setting forces the unit to interrogate only the local 
monitor and DEFAULT uses only the pre-programmed settings.
DDC Refresh
Settings: AT START, DISABLED
AT START
 sets the ServSwitch CX to read DDC information from the selected 
source at power up. When DISABLED, no new DDC data is sought and existing 
information is used. When viewing this menu, press F8 to discover DDC 
information from the chosen source immediately. 
To get here
1  From a local, remote or global keyboard, 
log on as ‘admin’ user.
2  Press 
 
   (hotkeys can change).
3  Press   to select ‘More menus’.
4  Select ‘Global Preferences’.