Black Box KV9804A Manual De Usuario

Descargar
Página de 35
Chapter 3: Installation
724-746-5500   |   blackbox.com 
Page 17
3.4.2 Control by RS-232 serial
Where the external control is via RS-232 signal, ensure that the configuration menu option   is set to   or   to enable RS-232 
control.   
3.4.2.1 Serial port parameter settings
Ensure that the chosen serial port is configured to the following:
•  Baud rate:  
To match setting of   option in the Configuration menu
•  Data bits:  
8
•  Stop bit:  
1
•  Parity: 
None 
3.4.2.2 Serial port channel selection codes
  
ASCII 
 
Character Hex  Decimal
•  Channel 1:  
‘1’ 
0x31 
49
•  Channel 2:  
‘2’ 
0x32 
50
•  Channel 3:  
‘3’ 
0x33 
51
•  Channel 4:  
‘4’ 
0x34 
52
Note: As each channel is chosen using the above RS-232 commands, the peripherals that will be transferred are determined by 
the current setting of the switching mode.
3.4.2.3 Control by channel select input lines
Where the external control is via the four channel select input lines of the OPTIONS port (see pin out), ensure that the configura-
tion menu option   is set to   to enable the input lines.
The four input lines are suitable for connection to dry contacts or open collector style outputs. Connecting an input line to GND 
will cause the Wizard DP USB unit to switch all of its functions to the selected channel: 
•  Channel 1:   Channel select input 
1 low
•  Channel 2:   Channel select input 
2 low
•  Channel 3:   Channel select input 
3 low
•  Channel 4:   Channel select input 
4 low
If the input line is held low then all other switching requests by other means will be ignored until the line returns to a high (open) 
state.
If more than one logic input is low (closed) then the lower channel number takes priority.
Note: The input lines have only limited protection against over voltage.