Black Box LB9002A-ST-R2 Manual De Usuario

Descargar
Página de 16
Express Ethernet Switch 
12 
 
 
Table 8: Specifications per model 
 
Model 
Dimension "W x "D x "H 
Weight 
Output 
Pwr 
LB9002A-SC/ST 
10 x 5.3 x 1.4 
25.4 x 13.5 x 3.6 cm 
2.1 lb. 
0.9 kg 
100-250VAC 
47-63 Hz 
7W 
Installation 
Quick Tip 
Install a Black Box Express Ethernet Switch as a plug-and-play device. No special 
configuration is required. Details below are consistent with the installation of any electronic 
device 
 
Place the Black Box Express Ethernet Switch where it will not be subjected to extreme 
temperatures, humidity, or electromagnetic interference. Specifically, the site you select 
should meet the following requirements: 
 
??
The room temperature should be between 32 and 104 degrees Fahrenheit (0 to 40 
degrees Celsius). 
??
The relative humidity should be less than 90 percent, non-condensing. 
??
Surrounding electrical devices should not exceed the electromagnetic field (RFC) 
standards for IEC 801-3, Level 2 (3V/M) field strength. 
??
Make sure that the switch receives adequate ventilation. Do not block the ventilation 
holes on the side of the switch or the fan exhaust port on the rear of the switch. 
??
The power outlet should be within 1.8 meters of the switch. 
 
Connecting to Power 
Connect the supplied AC power cord to the receptacle on the back of the switch, and then 
plug the cord into a standard AC outlet with a v oltage range from 100 to 120 VAC. For 
external power supply units, plug the jack into the DC receptacle on the front of the unit, 
and plug the power supply unit into a 110~220 AC outlet. 
Turn the switch on by flipping the ON/OFF switch on the rear of the unit to the I (ON) 
position. The O position is OFF. 
 
Connecting to Your Network 
If you are making a connection to a server or workstation, be sure that it has a properly 
installed 100BASE-TX (or 100BASE-FX if the switch does not contain 100BASE-TX 
ports) network interface card. Connect the RX/TX jacks on the target device to the TX/RX 
jacks on the switch and the RJ-45 jacks on the target device to the RJ-45 jacks on the 
switch. 
 
Use the uplink port for connecting to a regular (i.e. non-uplink) port of a hub or another 
switch. If connecting to an uplink port of a hub or another switch, use any port. There is no 
uplink issue with fiber ports. 
 
Copper-based cabling 
Connect cables to computers or network segments into the RJ -45 ports on the front of the 
switch.