Barco DCS-200 Manual De Usuario
140
DCS-200 • User’s Guide
_K==oÉãçíÉ=`çåíêçä
Remote Commands
1:"1"
2:"2"
.
.
64:"64"
f`opq
•
Description: Reset Input Configuration to the input default values
•
Command Format: ICRST -i (input)
•
Parameters: -i (input): 1 - 9
•
Query Format: N/A
•
Query Response: N/A
f`p^s=
•
Description: Saves Input Configuration. The input’s IMAP is updated if the
-f (file) parameter is specified.
-f (file) parameter is specified.
•
Command Format: ICSAV -i (input) -f (file)
•
Parameters: -i (input):1 - 9
-f (file): 1 - 64. If specified, update the File Association menu to reflect
the selected file number. If not specified, use the current file number
from the ICREC query.
the selected file number. If not specified, use the current file number
from the ICREC query.
•
Query Format: N/A
•
Query Response: N/A
f`pm
•
Description: Input Colorspace Adjust
•
Command Format: ICSP -i (input) -c (color)
•
Parameters:
-i (input): 1 - 9
-c (color): 0-RGB, 1-SMPTE
•
Query Format: ICSP -i (input) -?
•
Query Response: ICSP -i (input) -c (color) --min 0 --max 1
•
List Format: Each input type will have a different list for colorspace.
ICSP -i (input) --list
fe^qs
•
Description: Input Horizontal Active Adjust. This command is only adjustable for
analog input types. Other input types will provide query information only.
analog input types. Other input types will provide query information only.
•
Command Format: IHATV -i (input) -a (active)