Product Manager Overview
If a gray square displays in the status bar (no Ethernet connection), a 
reason for the status displays in the Status table at the top of the 
Hardware View. Refer to 
Messages display to the right of the status symbol as you move the 
cursor over options under the menu bar menus. These messages 
provide additional details about tasks that you can perform through 
the menu option.
Table 1-1
Operating Status - Status Bar and Switch Status
Symbol
Status Bar
Switch Status Table Text
Meaning
Green Circle
Fully Operational 
All components and installed ports are 
operational; no failures. 
Yellow 
Triangle
Redundant Failure
A redundant component has failed, such 
as a power supply, and the backup 
component has taken over operation.
Minor Failure
A failure occurred which has decreased 
the switch operational ability. Normal 
switching operations are not affected.
• One or more ports failed, but at least 
one port is still operational.
• A fan has failed or is not rotating 
sufficiently.
Red 
Diamond 
with Yellow 
Background
NOT OPERATIONAL
A critical failure prevents the switch from 
performing fundamental switching 
operations.
• All fans failed.
• All installed ports failed.
• Both power supplies failed.
Gray Square
Never Connected
Link Timeout
Protocol Mismatch
Duplicate Session
Unknown Network Address
Incorrect Product Type
Switch status is unknown. This occurs if 
the Ethernet network connection between 
the EFC Server and the switch cannot be 
established or if the CTP fails. Refer to 
 on page 2-3 for details on 
the status table text.