 Provisioning guidelines
Default method
Studies have been conducted which estimate the average line 
 to
never be greater than 5.5 in 90 percent of all businesses. If attempts to
calculate the 
 using the comparative method or the manual
calculation have not been successful, the default-of 5.5 line 
 can be
used.
The network line usage is determined by multiplying the number of lines by
5.5 
 The total is then multiplied by 2 to incorporate the 
 Unfortunately, when this method is used, the intra 
 is added
twice to the equation, and the result could be over provisioning if the intra
 is high.
Another difficulty experienced with this method is the inability to forecast
individual trunk groups. The trunk and intra 
 is forecasted as a sum
group total. Examples of the Default method and the Manual calculation
method are shown in Table 3-4 for comparison.
Default method example:
 275 Stations at Cutover
 304
Stations at 2 years
 352
Stations at 5 years
Cutover 275 x 5.5 
 x 2 = 3025 CCS Total System Load
2 Year 304 x 5.5 
 x 2 = 3344 CCS 
Total System Load
5 Year 352 x 5.5 
 x 2 = 3872 
CCS Total System Load
System engineering 553-3001-151