ENGINEER TELEPHONE LINE
NOTES
Note: 
This module is reissued   change the minimum loop length requirement to
 
 and to add metric equivalents.
(I) Cable pair selections must meet the following requirements:
AC signal loss must be 
 than 12.9 
 at 256 
 due to all sources
 loop resistance must be less than 175 Ohm
Minimum loop length (mainframe bulkhead to telephone) of 30 m (100 ft)
Near end crosstalk coupling loss 
 at 
 frequency of 256 
(not an issue for typical 22, 24, and 26 AWG twisted pair cable)
No bridge taps are permitted
No loading coils are permitted
 Protection devices of the carbon-block and gas-filled type are permitted
if the off-state shunting impedance is better than 10 
 resistive,
and less than 
 capacitive.
(2) The following criteria have to be met where undercarpet cabling is used.
characteristic impedance at 256 
 
   10 Ohm
insertion loss at 256 
   4.6 
next pair-to-pair coupling loss at 256 
 > 
 
(3) For the typical system of 22, 24, or 26 AWG standard twisted pair cable,
the requirements translate to the following allowable loops.
. .
up to 915 m (3000 ft) of 22 or 24 AWG cable
up to 640 m (2100 ft) of 26 AWG cable
(4) If selected cable pair does not work satisfactorily. select another cable
pair using the following flowchart (Page 2):