Minicom Advanced Systems Smart CAT5 Manual De Usuario

Descargar
Página de 45
SMART CAT5 SWITCH – 108/116 
 
 
25
 
Input the DDC information of the monitor connected to the Smart CAT5 switch into 
the memories of all connected RoC/RICCs when first installing system. 
To input the DDC information:  
1.  Disconnect the Video cable of all RoC/RICCs from the computers. 
2.  Press Shift twice to open the OSD. 
3.  Press F10. “Please wait” flashes a few times and disappears. The monitor’s DDC 
information is sent to all RoC/RICCs. 
4.  Reconnect the Video cable of all RoC/RICCs. 
4.2.14.1 Updating the DDC information 
Update the DDC information in any of the following circumstances:  
·
  When replacing the monitor connected to Smart CAT5 Switch 
·
  When adding a new RoC/RICC to the system 
·
  When reconnecting an existing RoC/RICC that was temporarily used in a 
different system 
To update the DDC information, repeat the steps as set out above.