Network
If DHCP is activated (default), the obtained network data is 
displayed. Otherwise you can specify the network data manually:
Management LAN Settings (1)
IPv4 settings
IP Address is assigned by DHCP
Assign IP Address manually:
IP Address
Subnet Mask
Gateway
Management LAN Settings (2)
IPv4 settings
Obtain DNS address from DHCP
Assign primary and secondary Domain Servers
DNS Server 1
DNS Server 2
Power
Contains details of the power supply:
PSU Redundancy
 (No Redundancy)
PSU Dynamic Mode
 (ON)
PIN
Contains a four-digit PIN as password protection for the 
ServerView local service panel
Default values:
PIN enable
 (OFF)
PIN
 (0000)
Check
Ekeying Check: This is a function which allows you to query the 
compatibility of the modules before startup, and then activate, 
partially activate or deactivate the module depending on the 
result. For example, you would not activate modules whose 
operating voltages or power consumption are not compatible with 
the system.
This test begins automatically after switch-on or after a hardware 
replacement. If errors are found, you can find out more about 
them via the 
Details
 button. Replace the defective hardware 
component and repeat the test.