Fujitsu RX200 S2 Manual De Usuario
![Fujitsu](https://files.manualsbrain.com/attachments/6c4642b33d2edbd09f94719c20a133aa0e862902/common/fit/150/50/80a45702a21fefb1823bce6851e87db450dccf7792cb572ebc8a90330a68/brand_logo.png)
199
PRIMERGY RX200 S2 User’s Guide
Inst
allin
g I
allin
g I
nte
rn
al O
pti
ons
7
7.8.4 Replacing a Power Supply Unit when the Redundant
Function is Enabled
When the system power supply redundant function is enabled, a failed power supply unit can be
replaced without turning off the server.
After removing the power supply unit, be sure to install a new unit.
■ Power Supply Unit LED Status
■ Replacing the Power Supply Unit
1
Remove the power cable from the failed power supply unit.
2
Remove the failed power supply unit.
3
Install the new power supply unit.
4
Plug the power cable into the inlet of the new power supply unit.
Power supply unit LED
Green On: The unit is operating normally
Amber On: An AC power supply is connected
Amber On: An AC power supply is connected
or an error is detected in the
power supply unit
power supply unit