Fujitsu RX200 Manual De Usuario
Options Guide
27
Processors
Exchanging the heat sink
6.3
Exchanging the heat sink
Ê
Open the server as described in the chapter “Preparation” on page 15f.
Ê
Remove the ventilation duct (see page 20).
Ê
Remove the four screws of the heat sink in diagonally opposite sequence
(see page 24).
(see page 24).
Ê
Turn the heat sink carefully back and forth to loosen it. Then lift it out to
remove it.
remove it.
Ê
Clean the surface of the processor with a lint-free cloth.
Ê
Fit the heat sink on the processor such that the side labeled “FRONT” is
facing the front of the server (see page 23).
facing the front of the server (see page 23).
Ê
Attach the heat sink with four screws. Tighten the screws in diagonally
opposite sequence (see page 23).
opposite sequence (see page 23).
Ê
Reinstall the ventilation duct (see page 20).
Ê
Close the server, plug in the power plugs, and switch on the server as
described in the chapter “Completion” on page 45f.
described in the chapter “Completion” on page 45f.