DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-142
list mst 
8
  0x01 - Performed Requested Reset of Logical Channel
  0x06 - Resetting Logical Channel
  0x08 - processor channel connected
  0x09 - processor channel disconnected
Link Control
0xD2 - link control
R1 Message events:
  0x00 - Busy Out Link
  0x01 - Release Busied Out Link
  0x0A - Level 3 Restarting
R3 Message events:
  0x00 - Stop Link
  0x01 - Start Link
  0x0A - Level 3 Restarting
0xD3 - link status (R3 Only)
R3 Message events:
  0x02 - Session Down
  0x03 - Session Up
Session Sanity
0xE2 - X.25 Session Timer Expirations
Timers:
Message[1]
= interface link number
Message[2]
= message event
Message[1]
= interface link number
Message[2]
= message event
Message[1]
= processor channel number
Message[2]
= timer