Polycom RMX 1000 User Guide 
 
 
 
2-9 
Parameter 
Description 
System H.323 Alias 
Set the H.323 alias for the system. 
 
If your IP network type is H.323 only, go to step 8. 
To configure the SIP server, click the SIP Server tab, and configure 
related parameters in accordance with the table below: 
 
Figure 2-10 
IP Network Services –SIP Server 
Table 2-4 
Configuration Description of SIP Server Parameters 
Parameter 
Description 
IP Network Type 
Set the IP network type for the RMX 1000 system to make 
a call. You need to set it based on the call type used for the 
participant's endpoint. It can be set to: 
ƒ
 
H.323: 
Only H.323 calls are supported. 
ƒ
 
SIP: 
Only SIP calls are supported. 
ƒ
 
H.323 & SIP: 
H.323 and SIP calls are supported at the 
same time. 
Settings of the SIP server related parameters are available 
only when the SIP network type is selected. 
Transport Type 
Set the transport layer protocol used for communicating 
with the SIP server. It needs to be consistent with the 
protocol supported by the SIP server. 
Register to Server 
Specifies whether to register RMX 1000 to the specified 
SIP server. You need to set the SIP server related 
parameters after this function is enabled.   
Primary 
Server/Alternate 
Server 
Displays the registration status of the SIP server. 
When registration of the preferred server fails, the 
alternate server will function as the current in-use SIP 